Discussion:
MPC5566 Time Base
S***@eaton.com
2009-09-30 18:51:18 UTC
Permalink
The e200z6 reference identifies the HID0[SEL_TBCLK] bit to select the
time base from either the processor clock or the p_tbclk input. I
cannot find in that reference or the MPC5566 reference any mention of
where the p_tbclk input comes from. Anyone know what it is?



Thanks





[Non-text portions of this message have been removed]
Dees Randy-RSAF30
2009-09-30 19:14:18 UTC
Permalink
The p_tbclk input is connected to ground, therefore it has no function.
There is no alternate clock for the time base.

regards
randy

________________________________

From: ***@yahoogroups.com [mailto:***@yahoogroups.com] On Behalf
Of ***@eaton.com
Sent: Wednesday, September 30, 2009 1:51 PM
To: ***@yahoogroups.com
Subject: [MPC500] MPC5566 Time Base




The e200z6 reference identifies the HID0[SEL_TBCLK] bit to select the
time base from either the processor clock or the p_tbclk input. I
cannot find in that reference or the MPC5566 reference any mention of
where the p_tbclk input comes from. Anyone know what it is?

Thanks


.

<http://geo.yahoo.com/serv?s=97359714/grpId=6276387/grpspId=1706554205/m
sgId=4018/stime=1254336699/nc1=1/nc2=2/nc3=3>




[Non-text portions of this message have been removed]

Loading...